Measurement And Instrumentation(Electrical Engineering ) Questions and Answers
Question 1. One single phase wattmeter operating on 230V and 5A for 5 hours makes 1940 revolutions. Meter constant in revolutions is 400. What is the power factor of the land?
1
0.84
0.73
0.65
Explanation:-
Answer: Option B. -> 0.84
Question 2. The spring material used in a spring control device should have the following property.
Should be nonmagnetic
Most be of low temperature coefficient
Should have low specific resistance
All of the above
Explanation:-
Answer: Option D. -> All of the above
Question 3. A moving iron ammeter may be compensated for frequency errors by
A shunt resistance
A series inductance
Shunt capacitance
Series resistance
Explanation:-
Answer: Option C. -> Shunt capacitance
Question 4. Which of the following meters has a linear scale?
Thermocouple meter
Moving iron meter
Hot wore meter
Moving coil meter
Explanation:-
Answer: Option D. -> Moving coil meter
Question 5. Why is a MISC meter not recommended for DC measurement?
The meter is calibrated for AC and it’s error for DC would be high
The meter does not respond to DC signals
The error is high due to hysteresis effect
The error is high due to eddy current effect
Explanation:-
Answer: Option C. -> The error is high due to hysteresis effect
Question 6. The problem of Electrostatic coupling in a transformer is acute at
Low frequencies
Power frequencies
High frequencies
High load on the transformer
Explanation:-
Answer: Option C. -> High frequencies
Question 7. Electrostatic instruments are normally used for
Low current measurements
High current measurements
Low voltage measurements
High voltage measurements
Explanation:-
Answer: Option D. -> High voltage measurements
Question 8. Which meter is suitable for the measurement of 10mV at 50MHz?
Moving iron voltmeter
VTVM
Moving coil voltmeter
CRO
Explanation:-
Answer: Option D. -> CRO
Question 9. Which of the following devices should be used for accurate measurement of low D.C. voltage?
Small range moving coil voltmeter
D.C. potentiometer
Small range thermocouple voltmeter
None of the above
Explanation:-
Answer: Option B. -> D.C. potentiometer
Question 10. An instrument to be used for measurement and control should preferably have
Dead zone and dead time
Linear output and fast response
Non-linear output
A highly damped response
Explanation:-
Answer: Option B. -> Linear output and fast response